{"product_id":"climax-741-atemschutz-vollmaske-klasse-3","title":"Climax full-face respirator 741, Class 3","description":"\u003cp\u003eThe Climax 741 class 3 full-face respirator complies with EN 136:1998 and combines a close-fitting TPE mask body with a polycarbonate panoramic visor. The Rd40 screw connection according to EN 148-1 accepts the specified Climax 725 filters. The 5-point harness allows even adjustment to the face.\u003c\/p\u003e\n\u003ch2\u003eRd40 filter connection and visor\u003c\/h2\u003e\n\u003cp\u003eThe Rd40 connection is designed for Climax 725 gas, particle and combination filters. Even where the thread fits mechanically, use only a combination approved by the manufacturer. The filter type must suit the contaminant and its concentration. The scratch-resistant panoramic visor has optical class 1 and impact-resistance marking F according to EN 166:2001.\u003c\/p\u003e\n\u003ch2\u003eMask body and fit\u003c\/h2\u003e\n\u003cp\u003eThe flexible sealing lip must contact the face continuously. Tighten the straps evenly and perform the seal check according to the manufacturer’s instructions before every use. Beards, hair or unsuitable spectacle arms in the sealing area can cause leaks.\u003c\/p\u003e\n\u003ch2\u003eLimits of filter respirator protection\u003c\/h2\u003e\n\u003cp\u003eDo not use the mask with unknown contaminants or in an immediately dangerous atmosphere. The manufacturer also excludes substances with poor warning properties and chemicals that react strongly exothermically in the filter. Containers, tunnels and other areas where oxygen deficiency is possible require properly planned breathing apparatus independent of ambient air.\u003c\/p\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Productos Climax\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e 741\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eProtection class:\u003c\/strong\u003e Class 3 according to EN 136:1998\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFilter connection:\u003c\/strong\u003e EN 148-1, Rd40\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eVisor:\u003c\/strong\u003e Polycarbonate, optical class 1, impact resistance F according to EN 166:2001\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMask body:\u003c\/strong\u003e Thermoplastic elastomer (TPE)\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHarness:\u003c\/strong\u003e 5-point\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 435 g\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOxygen environment:\u003c\/strong\u003e Only in atmospheres with more than 19.5% oxygen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eWhich filters fit this full-face respirator?\u003c\/h3\u003e\n\u003cp\u003eThe Climax 741 has an Rd40 connection according to EN 148-1 for the Climax 725 filter range. Select the filter type based on the hazardous substance, concentration and working conditions; the connection alone does not determine protection.\u003c\/p\u003e\n\u003ch3\u003eWhat does mask class 3 mean?\u003c\/h3\u003e\n\u003cp\u003eClass 3 describes a full-face mask for particularly demanding use. The design class is not an FFP class and alone specifies neither the permitted contaminant concentration nor the service duration.\u003c\/p\u003e\n\u003ch3\u003eWhat do optical class 1 and F mean for the visor?\u003c\/h3\u003e\n\u003cp\u003eOptical class 1 concerns optical quality. F indicates tested impact resistance against particles with low impact energy. These two details must not be confused with the filter’s respiratory protection.\u003c\/p\u003e\n\u003ch3\u003eCan I use the mask in an oxygen-deficient atmosphere?\u003c\/h3\u003e\n\u003cp\u003eNo. The mask does not supply oxygen. The manufacturer requires more than 19.5% oxygen by volume. This filter mask is unsuitable for an unknown atmosphere or an immediate danger to life and health.\u003c\/p\u003e\n\u003ch3\u003eHow do I clean the mask after use?\u003c\/h3\u003e\n\u003cp\u003eRemove the filter before cleaning and do not wash it. Clean the mask parts according to the manufacturer’s instructions with a suitable mild cleaner, rinse carefully and dry without direct heat. Check the sealing lip, valves, visor and straps before the next use.\u003c\/p\u003e\n\u003ch3\u003eCan I wear the full-face mask with a beard?\u003c\/h3\u003e\n\u003cp\u003eThere must be no facial hair in the sealing-line area. Even short stubble can impair the seal. Tightening the harness firmly cannot reliably compensate for a leaking seal.\u003c\/p\u003e","brand":"Climax","offers":[{"title":"Default Title","offer_id":65073132044637,"sku":"9127","price":77.49,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1068\/5520\/3165\/files\/atemschutzvollmaske-klasse-3-kaufenjpg-11969277.jpg?v=1782382634","url":"https:\/\/brixoro.eu\/en-lu\/products\/climax-741-class-3-full-face-respirator-rd40","provider":"Brixoro","version":"1.0","type":"link"}